Guidelines for Determining Medical Blister Packaging Shelf Life: Analysis of Scientific Validation and Regulatory Requirements

Guidelines for Determining Medical Blister Packaging Shelf Life: Analysis of Scientific Validation and Regulatory Requirements

Time:2025-07-30 10:50:25 Source:Dongguan Yinso Medical Packaging Co.,Ltd. Views:185

In the medical device industry, determining the product packaging shelf life is far more than a simple date label—it is a critical process that requires rigorous scientific validation. The international standard ISO 11607-1 clearly stipulates that a dual-validation mechanism must be implemented to ensure the reliability of the packaging system.

 

According to ISO 11607-1, the determination of medical blister packaging shelf life must be based on stability testing data. This validation work involves two key types of testing: real-time aging studies and accelerated aging studies.

 

Real-time aging studies involve long-term observation under standard environmental conditions (typically 23±2°C and 50±5% relative humidity). This "natural aging" approach yields the most authoritative data and is regarded by global regulatory agencies as the "gold standard." The U.S. FDA emphasizes in 21 CFR 820.130 that packaging validation must accurately reflect real-world usage conditions.

 

Accelerated aging studies, on the other hand, shorten the testing period by exposing the packaging to elevated temperatures, based on the Arrhenius reaction rate model. While this method cannot fully replace real-time aging studies, ISO 11607-1 permits accelerated aging data to serve as a provisional basis for determining shelf life during the initial product launch phase. The EU Medical Device Regulation (MDR) Annex I, Section 8.3 also recognizes this approach, allowing manufacturers to use accelerated testing results before real-time data becomes available.

 

It is important to note that ISO 11607-1 sets specific conditions for the use of accelerated aging data:

 

Accelerated data may serve as a temporary basis for shelf life until real-time aging data is obtained.

 

If historical data demonstrates that there is no time-dependent interaction between the product and the sterile barrier system, such data may continue to validate packaging integrity.

 

China’s NMPA further stipulates in its "Medical Device Registration Submission Requirements" that manufacturers must submit real-time aging data for at least one batch.

 

Key Consideration: Packaging-Product Interaction

Per ISO 10993-12 (biocompatibility requirements), if a medical device may release volatile substances (e.g., ethylene oxide sterilization residues) or if packaging materials could interact with the product (e.g., material migration), the packaging shelf life must be evaluated in conjunction with the device’s functional stability. In such cases, ISO 11607-1 recommends conducting device performance stability testing alongside packaging stability testing.

 

Industry Best Practices

Experts recommend that companies develop a comprehensive validation plan early in product development. A successful case involves a Class III orthopedic device manufacturer that used 55°C accelerated aging for 12 weeks to simulate a 2-year shelf life, while simultaneously conducting real-time monitoring under ambient conditions. This "dual-track" approach met both time-to-market requirements and scientific reliability, though it requires periodic review of historical data, especially after material or process changes.

 

Critical Reminder: Packaging vs. Product Expiry

ISO 13485:2016, Clause 7.5.1, explicitly states that if a device’s functional expiry is shorter than its packaging shelf life, the device’s expiry date takes precedence and must be clearly labeled. This requirement is mandatory in all major global markets.

 

Conclusion

Determining the shelf life of medical blister packaging is a systematic process that integrates scientific validation and regulatory compliance. Manufacturers must not only understand the deeper requirements of the standards but also develop tailored validation strategies based on product characteristics—ensuring both regulatory adherence and efficient market entry.


Contact Us

  • E-mail:

    info@yinsopack.com

  • Tel:

    +86 15014837000(Wechat/WhatsApp/Skype)

  • Address:

    NO.59 Meilin Road, Dalingshan Town, Dongguan City,Guangdong Province, China

  • 7x24 hours On Iine Service

Need Packaging That Passes Audits & Protects Products?

Get a Free Prototype + Compliance Report Within 5 Days

Dongguan Yinso Medical Packaging  Co.,Ltd.

Yinso Packing has been a leading figure in the medical packaging industry since 2007. We are committed to providing reliable, cost - effective, and innovative rigid thermoformed packaging solutions to top medical companies.

© 2025 Dongguan Yinso Medical Packaging Co.,Ltd All Rights Reserved.

Contact Us

AddressNO.59 Meilin Road, Dalingshan Town, Dongguan City,Guangdong Province, China

Emailinfo@yinsopack.com

Tel(Wechat/WhatsApp/Skype)+86 15014837000

  • AddressNO.59 Meilin Road, Dalingshan Town, Dongguan City,Guangdong Province, China
  • Emailinfo@yinsopack.com
  • Tel(Wechat/WhatsApp/Skype)+86 15014837000
© 2025 Dongguan Yinso Medical Packaging Co.,Ltd All Rights Reserved.